「
Researchers Develop Clinically Validated Wearable Ultrasound Patch For Continuous Blood Pressure Monitoring
」を編集中
2025年9月19日 (金) 04:53時点における
BethanyLittlefie
(
トーク
|
投稿記録
)
による版
(
差分
)
← 古い版
|
最新版
(
差分
) |
新しい版 →
(
差分
)
ナビゲーションに移動
検索に移動
警告: このページの古い版を編集しています。
公開すると、この版以降になされた変更がすべて失われます。
警告:
ログインしていません。編集を行うと、あなたの IP アドレスが公開されます。
ログイン
または
アカウントを作成
すれば、あなたの編集はその利用者名とともに表示されるほか、その他の利点もあります。
スパム攻撃防止用のチェックです。 けっして、ここには、値の入力は
しない
でください!
<br>The wearable ultrasound patch builds upon an earlier prototype that was pioneered by the lab of Sheng Xu, [https://wiki.dulovic.tech/index.php/Home_Health_Care_In_The_Warren_Area BloodVitals SPO2] a professor within the Aiiso Yufeng Li Family Department of Chemical and Nano Engineering at UC San Diego. Researchers re-engineered the patch with two key enhancements to reinforce its performance for continuous blood pressure monitoring. First, they packed the piezoelectric transducers closer together, [https://wiki.internzone.net/index.php?title=Benutzer:CarmaUnaipon2 BloodVitals SPO2] enabling them to provide wider coverage so they may higher target smaller arteries such because the brachial and radial arteries, which are more clinically relevant. Second, they added a backing layer to dampen redundant vibrations from the transducers, resulting in improved signal readability and tracking accuracy of arterial partitions. In assessments, the gadget produced comparable outcomes to a blood pressure cuff and one other clinical system called an arterial line, [https://www.taylordentist.com/how-to-reduce-dental-plaque-and-tartar/ BloodVitals SPO2 device] which is a sensor inserted into an artery to constantly monitor blood stress. While the arterial line is the gold customary for blood stress measurement in intensive care items and working rooms, it is very invasive, [https://gummipuppen-wiki.de/index.php?title=Benutzer:LawannaFsv BloodVitals insights] limits patient mobility, [https://psychowiki.edominium.com/wiki/index.php/U%C5%BCytkownik:MaxPatnode59 BloodVitals home monitor] and could cause ache or discomfort.<br><br><br><br>The patch provides a simpler and [https://www.fschuppisser.ch/exeblog2/blogdesk-button-20090810145931-gif-2 BloodVitals home monitor] more reliable different, as shown in validation tests carried out on patients undergoing arterial line procedures in cardiac catheterization laboratories and [https://marketingme.wiki/wiki/Blood_Oxygen_SPO2_Calculator BloodVitals home monitor] intensive care units. Researchers performed in depth tests to validate the patch’s security and accuracy. A total of 117 topics participated in studies that evaluated blood pressure across a wide range of actions and settings. In one set of tests, [https://wiki.lovettcreations.org/index.php/How_Can_We_Improve_Air_Quality wireless blood oxygen check] seven individuals wore the patch during each day activities equivalent to cycling, elevating an arm or leg, performing psychological arithmetic, meditating, [https://avdb.wiki/index.php/User:MartaBourget12 BloodVitals home monitor] eating meals and consuming energy drinks. In a larger cohort of 85 topics, the patch was tested throughout changes in posture, equivalent to transitioning from sitting to standing. Results from the patch closely matched these from blood stress cuffs in all tests. The patch’s means to continuously [https://wavedream.wiki/index.php/User:CVHDeneen841 BloodVitals home monitor] blood pressure was evaluated in 21 patients in a cardiac catheterization laboratory and 4 patients who had been admitted to the intensive care unit after surgery. Measurements from the patch agreed intently with results from the arterial line, [https://amconsultingafrique.com/lights-winged-seasons-fish-abundantly-evening/ BloodVitals home monitor] showcasing its potential as a noninvasive alternative.<br><br><br><br>"A big advance of this work is how thoroughly we validated this expertise, thanks to the work of our medical collaborators," stated Xu. "Blood stress may be all around the place depending on elements like white coat syndrome, masked hypertension, each day actions or use of medicine, which makes it tough to get an accurate prognosis or handle remedy. That’s why it was so essential for us to test this machine in a large number of real-world and clinical settings. The analysis team is preparing for giant-scale clinical trials and plans to combine machine learning to further improve the device’s capabilities. Efforts are additionally underway to validate a wireless, battery-powered model for long-time period use and seamless integration with existing hospital systems. Baiyan Qi, Xinyi Yang, Xiaoxiang Gao, Hao Huang, Xiangjun Chen, Yizhou Bian, Hongjie Hu, Ray S. Wu, Wentong Yue, Mohan Li, Chengchangfeng Lu, Ruotao Wang, Siyu Qin, Isac Thomas, Benjamin Smarr, Erik B. Kistler, Belal Al Khiami, Irene Litvan and Sheng Xu, UC San Diego; and Esra Tasali and Theodore Karrison, The University of Chicago.<br><br><br><br>Issue date 2021 May. To attain extremely accelerated sub-millimeter resolution T2-weighted practical MRI at 7T by developing a 3-dimensional gradient and spin echo imaging (GRASE) with internal-quantity selection and variable flip angles (VFA). GRASE imaging has disadvantages in that 1) okay-house modulation causes T2 blurring by limiting the number of slices and 2) a VFA scheme ends in partial success with substantial SNR loss. In this work, accelerated GRASE with controlled T2 blurring is developed to improve a point unfold perform (PSF) and temporal signal-to-noise ratio (tSNR) with a large number of slices. Numerical and experimental studies had been carried out to validate the effectiveness of the proposed methodology over common and VFA GRASE (R- and V-GRASE). The proposed method, whereas achieving 0.8mm isotropic decision, purposeful MRI in comparison with R- and V-GRASE improves the spatial extent of the excited volume up to 36 slices with 52% to 68% full width at half maximum (FWHM) reduction in PSF but approximately 2- to 3-fold mean tSNR enchancment, thus leading to larger Bold activations.<br>
編集内容の要約:
鈴木広大への投稿はすべて、他の投稿者によって編集、変更、除去される場合があります。 自分が書いたものが他の人に容赦なく編集されるのを望まない場合は、ここに投稿しないでください。
また、投稿するのは、自分で書いたものか、パブリック ドメインまたはそれに類するフリーな資料からの複製であることを約束してください(詳細は
鈴木広大:著作権
を参照)。
著作権保護されている作品は、許諾なしに投稿しないでください!
編集を中止
編集の仕方
(新しいウィンドウで開きます)
案内メニュー
個人用ツール
ログインしていません
トーク
投稿記録
アカウント作成
ログイン
名前空間
ページ
議論
日本語
表示
閲覧
編集
履歴表示
その他
検索
案内
メインページ
最近の更新
おまかせ表示
MediaWikiについてのヘルプ
ツール
リンク元
関連ページの更新状況
特別ページ
ページ情報