「
With Both Sorts Of Incandescent Bulbs
」を編集中
ナビゲーションに移動
検索に移動
警告:
ログインしていません。編集を行うと、あなたの IP アドレスが公開されます。
ログイン
または
アカウントを作成
すれば、あなたの編集はその利用者名とともに表示されるほか、その他の利点もあります。
スパム攻撃防止用のチェックです。 けっして、ここには、値の入力は
しない
でください!
<br>A multifaceted reflector (typically abbreviated MR) gentle bulb is a reflector housing format for halogen as well as some LED and fluorescent lamps. MR lamps have been originally designed for use in slide projectors, but see use in residential lighting and retail [https://stir.tomography.stfc.ac.uk/index.php/A_100-watt_Incandescent_Bulb_Produces_1 EcoLight home lighting] as nicely. They are suited to applications that require directional lighting comparable to track lighting, [https://healthwiz.co.uk/index.php?title=Demystifying_LED_Bulb_Conversion:_Tips_On_How_To_Upgrade_Your_Lighting EcoLight smart bulbs] recessed ceiling lights, desk lamps, pendant fixtures, panorama lighting, retail display lighting, and bicycle headlights. MR lamps are designated by symbols akin to MR16 where the diameter is represented by numerals indicating items of eighths of an inch. Common sizes for common lighting are MR11 (11⁄8 inches, 35 mm) and MR16 (16⁄8 inches, fifty one mm), with MR8 (8⁄8 inch, 25 mm) and MR20 (20⁄8 inches, [http://138.197.82.200/mediawiki/index.php/Every_Part_It_s_Worthwhile_To_Find_Out_About_Tips_On_How_To_Exchange_Headlight_Bulbs_Efficiently EcoLight bulbs] 64 mm) used in specialty applications. Many run on low voltage rather than mains voltage alternating current so require a energy provide. 3,314,331 for a miniature reflector lamp in 1967. The innovation was utilizing the lamp rim, quite than the bottom, as the reference plane for focusing.<br><br><br><br>This allowed extra versatile electrical mounting preparations and extra precise focusing. Most MR lamps include a halogen capsule (or, bulb) built-in with a pressed glass reflector with a base conforming to bi-pin GU5.3 customary. The reflector controls the route and unfold of gentle forged from the lamp. Some lamps use an aluminum coating as a reflector. Others use selective dichroic coating that reflects visible mild and permits infrared radiation to go by way of. This type reduces heating of illuminated objects since less infrared radiation is current in the sunshine beam. Nonetheless, [https://wiki.snooze-hotelsoftware.de/index.php?title=LED_Aquarium_Lights EcoLight home lighting] dichroic lamps should only be utilized in compatible fixtures that can dissipate the heat. Dichroic lamps must not be fitted to recessed or enclosed luminaires with the IEC 60598 No Cool Beam image. The brightness of MR lamps may be adjusted when used with applicable light fixtures and dimmers. However, the shade temperature modifications considerably when the lamp is dimmed, shifting dramatically to the hotter finish of the spectrum.<br><br><br><br>Like all halogen lamps, MR lamps produce important heat and care must be taken to keep away from contact with skin or proximity to flammable materials when the lamp is on or has been on just lately. Halogen lamps (18 lm/W typical) are more energy efficient than common incandescent lamps (15 lm/W typical) however still fall far behind other extra-current sorts such as fluorescent lamps (80-100 lm/W), gas discharge lamps (100-200 lm/W relying on varieties), and [https://paintingsofdecay.net/index.php/The_LED_Shop_Australia%C2%AE_Low_Voltage_Mild_Bulbs_And_Globes EcoLight home lighting] LEDs (125-one hundred fifty lm/W typical in brilliant white depending on style). With each sorts of incandescent bulbs, [http://47.105.96.219:13001/kennethmcnutt1/ecolight-lighting3027/wiki/An+Entire+Guide+To+LED+Light+Circuit+Board EcoLight smart bulbs] useful life might be considerably shortened if their filaments expertise mechanical shock or vibration. Using an digital transformer with a gentle start characteristic can considerably lengthen life, as it reduces the characteristically excessive inrush current that happens initially when the lamp is chilly. Dimming also extends life considerably. MR lamps, like all quartz-halogen lamps, produce some undesirable ultraviolet light. Usually, this must be filtered out.<br><br><br><br>Additionally, the quartz capsules of the lamps might rupture or explode upon failure of the lamps. For these two causes, some MR lamps include a cowl glass that serves as an built-in ultraviolet filter and explosion shield. MR16 lamps missing this cowl require the usage of a fixture that incorporates an exterior [https://santo.kr:443/bbs/board.php?bo_table=free&wr_id=146268 EcoLight home lighting] piece of glass specifically designed to provide both ultraviolet and [https://andreacardona.com.co/los-cinco-inventos-que-han-contribuido-a-la-consecucion-de-los-derechos-de-las-mujeres/ EcoLight home lighting] bodily safety. MR lamps can be found in 10-75 watt power scores (150-800 lumens). MR lamps most often operate at 12 volts, [https://wiki.snooze-hotelsoftware.de/index.php?title=Why_Folks_Nonetheless_Use_Inefficient_Incandescent_Light_Bulbs long-life LED] although they're additionally available in other voltages. These lamps use a bi-pin connector for energy: 12-volt MR11 bulbs usually use a GU4 base, and 12-volt MR16 bulbs often use a GU5.Three base. The widespread 12-volt MR16 lamps, due to this fact, require a ferromagnetic or electronic transformer-sometimes misnamed as a ballast-to convert the 120- or 230-volt mains voltage to the extra-low voltage required by the lamp. Certain MR lamps can operate immediately on the mains voltage. These lamps typically use a GU10 flip-and-lock base, so they can't be accidentally interchanged with low-voltage lamps.<br><br><br><br>GU10 is distinguished from the lower-voltage MR lamps by the U-shaped ceramic base mount with a ten mm (pin heart-to-center distance) 2-pin bayonet mount. MR16 lamps with an integrated transformer are also accessible. These lamps have screw bases to fit commonplace medium-base Edison sockets. MR lamps are commonly available in range of colour temperatures, from about 2700 Okay to 7000 Okay, to satisfy various applications. Retrofit lamps that generate gentle by a special precept but makes use of the MR form-factor can be found. For instance, LED-primarily based MR16 lamps appear just like halogen lamps and will be used in most fixtures designed for [http://wiki.die-karte-bitte.de/index.php/Sunrise-like_Alarm_Clock_Via_Residence_Assistant_Android EcoLight brand] MR lamps. The identical is true of MR11-compatible LED lamps. Fixtures designed for halogen MR16 or MR11 lamps that use digital transformers could need to be retrofitted with LED-suitable transformers. There may be a wide number of designs, various significantly with regard to beam width, mild color, [https://healercounselor.com/grace-elizabeth-hathaway/garcie2/ EcoLight home lighting] efficiency and luminous power.<br>
編集内容の要約:
鈴木広大への投稿はすべて、他の投稿者によって編集、変更、除去される場合があります。 自分が書いたものが他の人に容赦なく編集されるのを望まない場合は、ここに投稿しないでください。
また、投稿するのは、自分で書いたものか、パブリック ドメインまたはそれに類するフリーな資料からの複製であることを約束してください(詳細は
鈴木広大:著作権
を参照)。
著作権保護されている作品は、許諾なしに投稿しないでください!
編集を中止
編集の仕方
(新しいウィンドウで開きます)
案内メニュー
個人用ツール
ログインしていません
トーク
投稿記録
アカウント作成
ログイン
名前空間
ページ
議論
日本語
表示
閲覧
編集
履歴表示
その他
検索
案内
メインページ
最近の更新
おまかせ表示
MediaWikiについてのヘルプ
ツール
リンク元
関連ページの更新状況
特別ページ
ページ情報